FhSim
3.1.0
Marine systems simulation
|
| ID | 0466 |
| Class | BUG |
| Severity | 1 |
| Status | ready |
Models: MooringCable
Found: 2026-11-24, VD model lead (seabed static start, plan VD task M6, ENV-0160, merged at baccadc)
src/trawl_mooring_interaction/MooringCable.cpp:678-684 calls the seabed start. It places the elements on the seabed catenary with trawl_mooring::LayOnSeabedCatenary(shape, PreTensionTotalLength, coordinates, elements, states), and the joints between the elements stay open. LumpedMass and RbCable start with closed joints.
On an E6a-like line (700 m, OC4) the end force is 52 kN at t = 0. It then settles to about 30.16 kN, against the 30.2 kN catenary. A quasi-static case does not start at its end state, as the SeabedStart parameter promises (MooringCable.h:107).
Place the joints on the seabed curve in LayOnSeabedCatenary, so the start force equals the catenary force. The change touches only the start state of lines with a lying part. Other start layouts stay as they are.
A start test on an E6a-like line (700 m, OC4): the end force at t = 0 matches the catenary force (30.2 kN) within a small tolerance, and it does not settle after the start.