FhSim
3.1.0
Marine systems simulation
|
| ID | 0465 |
| Class | KNOWN-LIMITATION |
| Severity | 1 |
| Status | ready |
Models: —
Found: 2026-11-24, plan VD task M6 (feature seabed-static-start)
TrawlCable (src/trawl_mooring_interaction/TrawlCable.h) has no static seabed start. A warp is coupled to the trawl door, so it should not start on the seabed by default.
A warp that lies on the seabed at the start creeps to rest under the regularised seabed friction.
Add an opt-in parameter SeabedStart (default 0) for lying cables. When set, use the seabed catenary solver (fhsim_environment/seabed/SeabedCatenary.h) and InternalCable::InitializeStatesOnSeabed.
With SeabedStart = 1 a lying cable has near zero speed at T = 0. With the default 0 the result files stay identical.
None for existing decks, because the default is off.