FhSim  3.1.0
Marine systems simulation
Loading...
Searching...
No Matches
0465 — TrawlCable: optional static seabed start
ID 0465
Class KNOWN-LIMITATION
Severity 1
Status ready

Models: —

Found: 2026-11-24, plan VD task M6 (feature seabed-static-start)

Evidence

TrawlCable (src/trawl_mooring_interaction/TrawlCable.h) has no static seabed start. A warp is coupled to the trawl door, so it should not start on the seabed by default.

Effect

A warp that lies on the seabed at the start creeps to rest under the regularised seabed friction.

Possible fix

Add an opt-in parameter SeabedStart (default 0) for lying cables. When set, use the seabed catenary solver (fhsim_environment/seabed/SeabedCatenary.h) and InternalCable::InitializeStatesOnSeabed.

Test that would prove it

With SeabedStart = 1 a lying cable has near zero speed at T = 0. With the default 0 the result files stay identical.

Risk

None for existing decks, because the default is off.