FhSim
3.1.0
Marine systems simulation
|
| ID | 0130 |
| Class | KNOWN-LIMITATION |
| Severity | 1 |
| Status | blocked |
Models: —
Found: 2026-10-24, review doc/reviews/fhsim_environment-2026-10-24/README.md (plan P3, ENV-R5 d), confirmed at d0d8548
Decision needed: a sample of real SINMOD files, to learn which dimension orders occur. The plan leaves this to a follow-up until then.
src/environment/util/NetCDFParser.cpp, read_variable_info_from_file, checks that each required dimension is present, not their order. read_dynamic_variable_data reads the data as if the order were (time, zc, yc, xc), and depthMatrix as (yc, xc).
A file with another dimension order is read transposed: the right sizes, the wrong numbers, no error.
Compare the order of variable.ncvar.getDim(i) with the expected one and report the variable and the two orders; or read through the dimension names so any order works.
A small file whose u-velocity has the dimensions (time, zc, xc, yc) (the helper WriteGrid in tests/NetCdfSeafloorBathymetry_Test.cpp can take the order) must be refused with the variable named, or read correctly.
A check that is stricter than the real files would refuse files that work today. Needs real SINMOD files first.